Model to be inserted in a pipe, vertically mounted with housing made of Brass.

The flow switches are used to control the flow in tubes and pipes in which waters, oil, chemical products, etc. are used.

There is free movement system inside the device. When the liquid flow of the pipe pulls the paddle actuates a REED switch.

The switch has to be insterted between a pipe using the thread proccess connection depending on the model.

The models must be vertically mounted (±15º).

The indication arrow in the body has to be faced to the flow.

For a proper function, the device must be installed in straigh pipes with a mininum length at least of five times the diameter and far from valves or filters to avoid turbulence.

Dimensions

Approximate measures given in mm.

Technical data

NameFlow switch
TypeLIT-VL – ref: 2606-4
Maximum pressure+10 bar (+20º C)
Cable output2 wires x 2 meter
Maximum voltage250 V AC and 200 V DC
Contact function1 NO (Closed with flow)
Capacity of the contact1 A, 40 W (resistive load)
For capacitive or inductive loads
reduce at 50%
Ambient temperature-30° C – +100° C
Minimum flow1 l/min (not adjustable)
ProtectionIP65 according to DIN EN60529
Weight0,36 Kg
Materials:
HousingBrass
PaddleNoryl
CableDouble insulation PVC