Name | Membrane level indicator |
---|---|
Type | CD 2M – ref: 2204... |
Density of the product | 0,3 t/m3 – 2,5 t/m3 |
Ambient pressure | Atmospherical |
Maximum pressure | +0,5 bar |
Cable entry | M20x1,5 |
Maximum voltage | 250 V AC |
Contact function | 1 NO + 1 NC |
Capacity of the contact | 15 A / 250 V AC
(for resistive loads) For inductive or capacitive loads reduce at 50% |
Ambient temperature | -20º C – +70º C |
Protection | IP65 , Según DIN EN60529 |
Weight | 0,73 Kg |
Sensitivity | 60 – 200 g adjustable |
Materials: | |
Housing | Glass reinforced Polyester |
Membrane | NBR (Under request Viton) |
Mounting ring and screws | Zincated Steel (Under request Stainless Steel 1.4301) |
- Productos
- Control of solids
- CD 2M
Intended use
Versatile double membrane level indicator. Is to be used to control the maximum or minimum level of bulk solids in silos or vessels where an additional protection of the membrane is required. Due to the double membrane, the device can still work unless the erosion or breaking of the exterior membrane.
These controllers consist of a switch actuated by a membrane and it is recommended for dusty and powdery, granulated and grainy bulk goods like dust, flour, grain, sand, plastic, etc. with an easy flow and a bulk density from 0.3 to 2.5 t/m3.
Function
The membrane must to be exposed to the material.
The movement of the switch is the result of the pressure exerted by the incoming bulk material against the membrane which forces the membrane to move backwards, reversing the position of the switch and the signal is used for example to control the transport system in the silo.
The models “A-100”, “AD”, “SR” y “CD2M” and the models with S.S. membrane have a regulation system by a spring that allows the adjustment of the sensitivity. Tightening the regulation nut to reduce the sensitivity and increase the strain of the material to activate the microswitch. Clockwise insensitive.
The models are adjusted at their maximum sensitivity. It is necessary to ensure the proper pressure to the membrane that returns the membrane when there is no product covering it.
Mechanical connection
Drill holes in the silo or vessel and mount the indicator using screws, rods, fasteners or nuts M6 making sure of the easy flow of the material and ensure that the product leaves the membrane without product on it.