Name | Float switch |
---|---|
Type | BLB ATEX – ref: 2513-A-001 |
Certifications: | |
Dust | ATEX II 2D IP65 100º C |
Gas | ATEX II 2G EEx d IIB T5 |
Product density | 0,65 Kg/l |
Maximum pressure | +15 bar |
Cable entry | G 1/2 " |
Switching voltage | 250 V AC |
Switching function | 1 NO + 1 NC |
Capacity of the contact | 3 A / 250 V AC (for resistive loads) For inductive or capacitive loads, reduce at 50% |
Ambient temperature | -20° C – +100° C |
Protection | IP65 according to DIN EN60529 |
Weight | 1,50 Kg |
Materials: | |
Housing | Aluminium |
Proccess connection | Stainless Steel 1.4301 |
Float | Stainless Steel 1.4301 |
- Productos
- ATEX controllers
- BLB ATEX
BLB ATEX
Intended use
Model with flange proccess connection.
The side mounting level switches are used to control the level in tanks and containers in which non-scaling or residual waters, oil, chemical products, etc. are used.
The models are certificated for use in potentially explosive Dust or Gas atmospheres hazardous areas.
Function
When the level of the liquid reaches the level of the float switch, the float changes its position an angle and activates a micro switch or a REED switch in high temperature models due to this deviation.
When the liquid level falls, the float moves back and the switch is disengaged.
Mechanical connection
Mount the indicator using screws, rods, fasteners, nuts, using the counterflange or through connecting pipe.
For a correct use of the level switch, the float must not touch the walls of the tank and it is necessary to ensure the free movement of the float.
For use in potentially explosive Dust or Gas atmospheres hazardous areas the installation must be done according to the Standard and Normative documents.